High Temperature Concentrated Sulfuric Acid Analyzer

About this item:

The high-temperature concentrated sulfuric acid analyzer adopts stable air separation technology, high-temperature corrosion-resistant conductivity sensor, and high-temperature concentrated sulfuric acid broken line function instrument. It is suitable for measuring sulfuric acid concentration at diluter outlet, circulating pump outlet, heater outlet and preheater outlet of sulfuric acid waste heat recovery device. It has the advantages of fast response, stability.

 

 

Specifications:

Type

HAS110A

HAS110W

Measuring range

H2SO4 96-100% 27.9-244US/cm

 

Resolution

H2SO4 0.01%

 

Accuracy

±0.01%

 

Broken line function meter

Model: XA96-100 Power24VDC
Output 4-20mA Range 96-100%

 

Temperature

Working temperature: 20-200°C
Meter temperature: -20-70°C

 

Working pressure

0.6MPa

 

Measuring medium

Sulfuric acid containing gas

Sulfuric acid not containing gas

Power

90-260VAC, 50/60HZ, 24VDC Optional

 

Connection

HG-T20592 DN25 PN1.6MPa

 

Dimension

1100*120*1200mm

 

Weight

65kg

49kg

 

Consumable Parts:

Bolt

Double thread screw
M12X72

Surface plating

PTFE

Insulating pad

Material

Engineering plastics

Bearing the torque

50N

Insulating pipe

Material

PTFE

Size

 

Features:

 

Ø Provides fast and accurate process measurement for automatic diluter water control

Ø Stable and reliable protection

Ø Protect waste heat recovery system from sulfuric acid corrosion

Ø Gas contained in high temperature concentrated sulfuric acid is separated cleanly

Ø Sensor static elimination and waterproofing Measuring flow constant flow stability

Ø 2-way 4-20MA output (sulfuric acid concentration, sulfuric acid temperature)

Ø Maintenance-free, simple installation, stable separator corrosion-resistant

The conductivity sensor of the high-temperature concentrated sulfuric acid analyzer is required to be electrically isolated from the process pipeline. The high-temperature insulating component equipped with the high-temperature concentrated sulfuric acid analyzer adopts engineering plastics that can continuously apply a temperature of 250 degrees and has excellent thermal insulation properties as the insulating pad, and the surrounding bolts are 304 Stainless steel, and PTFE corrosion material is sprayed on the surface to ensure that the high-temperature poly-insulation components are not corroded by dilute sulfuric acid.

TOP